Revolution oven start-up check list

Something went wrong, please try again.
Fields marked with (*) are mandatory
Customer information’s

Equipment Start-Up
(RE4-8 or RE8-16 = 9A, RE4-12 or RE8-24 = 9 A, RE4-16 or RE8-32=12A)
Pressure must be between 5 and 12 inH2O (W.C.)
Pressure must be between 5 and 12 inH2O (W.C.)
-0.01 to 0.00 inH2O (W.C.) when the burner is lit on low fire.
Must be at least 2.0 µA on low fire.
RE4-8/RE8-16 = 400ml (13.5oz), RE4-12/RE8-24 = 500ml (17oz), RE4-16/RE8-32 = 2 x 400ml (2 x 13.5oz)
(start-up completed)

User training